22mm sensing, 2Hz response, M30 thread; 10V ~ 30V supply and 0°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 22MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active lifecycle does not settle this sensor's RoHS conflict
Fast-moving targets are the wrong job. Slower metal-target changes are a more plausible fit, subject to the 2Hz response ceiling. E2EW-QX22B1D30 2M is Active across the lifecycle fields, so new design-in is reasonable on lifecycle grounds.
Production release must wait. The compliance field says RoHS Compliant while the specification says RoHS Non-Compliant. Obtain a part-specific declaration before approving the BOM; neither entry resolves the conflict on its own.
The 22mm reach cannot rescue a missed target event
2Hz is the listed response-frequency ceiling. A 22mm sensing distance gives the reach to assess, but it does not guarantee detection across target and mounting arrangements, and events beyond the 2Hz ceiling cannot be counted on to produce distinct output changes. A target trial has to establish both reach and event rate.
The 10V ~ 30V supply range sets the power-interface check; 30V is its upper listed boundary, not a transient-tolerance claim. The 0°C ~ 85°C operating range rules out stations outside those temperatures. The PNP-NO, 3-Wire output must match the controller input; it can't drop into a connection wired for a different output type.
M30 mounting commits the bracket and cable termination
The M30 threaded-cylinder constraint fixes the bracket concept; cable leads fix the harness termination. The stainless-steel body and IP67 rating make sense at an exposed industrial station, but the ingress rating cannot make an enclosure entry watertight by itself. For existing production, keep the lead termination in the build instructions; order the cable-lead configuration against that process rather than assuming a connectorized build.
IP67 still leaves the installation details open
IP67 does not supply a mounting drawing. A mounting drawing must settle bracket clearance; a wiring diagram must settle the PNP-NO, 3-Wire connection. The output-current limit is absent, leaving controller-input loading unresolved.
View the Win-Source product page for E2EW-QX22B1D30 2M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting RoHS entries for E2EW-QX22B1D30 2M before production release.
- Check the 2Hz response ceiling against the fastest target event.
- Reserve an M30 mounting position and a cable-lead termination.