Omron E2EW-QX22B1T30 5M: Active, with a RoHS hold

E2EW-QX22B1T30 5M Omron product image

22 mm sensing distance, 2 Hz response ceiling, M30 threaded body; check the PNP-NO wiring and RoHS conflict.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

The 22 mm sensing distance needs a real target check

22 mm is the listed sensing-distance ceiling. Active lifecycle signals support new design-in once the sensing geometry is checked and the RoHS contradiction is resolved, but that figure is not a guaranteed switching gap for every target. The 10 V to 30 V supply bounds tell you whether the installed rail is eligible; they don't specify sensor current draw or output drive. A wrong gap means a missed part.

A 2 Hz ceiling rules out fast indexing

Fast indexing isn't the job. The 2 Hz response-frequency ceiling also does not establish switching delay for a moving target. For slower metal-presence checks, the PNP-NO, 3-wire output calls for a compatible input. The M30 threaded cylinder and cable leads dictate the bracket and cable route. IP67 and a stainless-steel body support exposed industrial mounting, but neither establishes chemical resistance or sealing after an unsuitable cable installation.

Active status does not settle the RoHS conflict

Can this part clear a controlled BOM? Its lifecycle signals say Active, but the compliance summary says RoHS Compliant and the specification says RoHS Non-Compliant. Box packaging is listed; that contradiction is the buying hold. Obtain a manufacturer RoHS declaration before release.

Temperature bounds still leave wiring and mounting open

The 0°C to 85°C range limits installation temperature but leaves hot-end sensing behavior unresolved. The listing lacks a pinout for the PNP-NO cable leads and an M30 mounting drawing, so neither input wiring nor bracket clearance is ready to freeze. It also omits the output load-current limit and the target conditions behind the 22 mm sensing-distance figure. Those details are needed before committing an input circuit and mechanical layout. The LED may help during commissioning, but it cannot rescue a miswired input.

View the Win-Source product page for E2EW-QX22B1T30 5M.

Key Takeaways for Engineers & Buyers

  • Keep the 2 Hz response ceiling out of fast indexing stations.
  • Match the input circuit to the 10 V to 30 V supply bounds and PNP-NO output.
  • Resolve the contradictory RoHS fields before releasing the BOM.