22mm sensing, 10V to 30V supply bounds and M30 thread; resolve the RoHS conflict before release.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

22mm sensing is not a stop-position guarantee

22mm is the listed sensing distance for E2EW-QX22B3T30 5M, not a guaranteed stop position for every metal target. Check the actual target before fixing that position. The lifecycle entries mark the part Active, but the conflicting RoHS entries block an unqualified release.

The listed supply bounds are 10V to 30V. 30V is a ceiling, not a working target, and those bounds alone do not settle voltage drop along the cable. The 0°C to 85°C operating-temperature range rules out an unheated installation that falls below 0°C, regardless of the IP67 ingress-protection rating.

A 2Hz response rules out fast part counting

Fast part counting is the wrong job for a sensor listed at 2Hz response frequency. Compare that rating with the machine’s actual detection cycle before using the sensor for an interlock or count input. For slower metal-presence checks, its shielded inductive design and M30 threaded stainless-steel body give the mechanical team a mounting approach, though the bracket still needs the drawing.

Match the PNP-NC/NO, 3-Wire output to the controller input and intended normal state. Cable leads also make termination an installation decision, not a connector choice to leave for later.

Can the conflicting RoHS entries be cleared for release?

Can this part go onto a new BOM under EU RoHS? Not yet. One compliance field says “RoHS Compliant,” while the part specifications say “RoHS Non-Compliant.” Obtain a declaration for this exact part and resolve the contradiction before release. Active status doesn’t settle it.

The missing drawings still decide the installation

The fit remains open. A mounting drawing must settle how the M30 body seats in its bracket; a wiring diagram must settle the cable-lead connections for the PNP-NC/NO output. A mistaken connection could leave the controller without the expected signal.

Target-material sensing curves are absent, so the listed 22mm distance cannot set the stop position for the actual workpiece. No output load limit is given, leaving the controller-input pairing open until that limit is known.

View the Win-Source product page for E2EW-QX22B3T30 5M.

Key Takeaways for Engineers & Buyers

  • Check the actual target against the listed 22mm sensing distance before fixing the stop position.
  • Keep the controls rail within the listed 10V to 30V supply bounds.
  • Resolve the conflicting RoHS entries for E2EW-QX22B3T30 5M before approving a new BOM.