Omron E2EW-QX22C130 2M: Active, but RoHS status conflicts

E2EW-QX22C130 2M Omron product image

22mm listed sensing distance, 10V ~ 30V supply bounds, M30 threaded body and 2Hz response frequency.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

The supply and target gap decide the first fit check

The 10V ~ 30V supply bounds and listed 22mm sensing distance set the first fit limits. Neither supply endpoint is a suggested setpoint; a rail outside those bounds rules the sensor out. Target spacing needs a check, too: 22mm is not a promise that every metal target will switch at that distance. The M30 threaded cylinder commits the mounting hardware to that form. A smaller hole is not an electrical workaround.

Active status leaves room for a new machine build

Active supports a new design-in. E2EW-QX22C130 2M is an inductive sensor for a metal target, not a general object detector. Put it opposite a nonmetal target and the sensing choice fails before the controller sees a signal. The stated 0°C ~ 85°C operating range is the environmental gate: below 0°C or above 85°C, the installation falls outside that range, regardless of the stainless-steel body.

IP67 is an ingress rating; it says nothing about chemical compatibility at a wash station. Cable leads let the machine builder route the connection from the threaded body, but the mounting must leave room for the cable. Every lifecycle signal says Active, but they don't settle the separate compliance conflict.

Can the RoHS entries support a production release?

Is this ordering code RoHS compliant? The compliance field says RoHS Compliant, while the specifications say RoHS Non-Compliant. EU RoHS status remains unresolved; obtain a manufacturer declaration for this ordering code before releasing a compliance-controlled build. Box packaging does not resolve the contradiction. The buying constraint is the conflicting declaration, not an end-of-life signal.

The 2Hz response limits what the output can catch

2Hz is the listed response frequency. Check the timing before assigning this sensor to count a fast-moving target. The LED can show a state change to a technician; it can't prove that the controller will capture a passing target. The NPN-NO, 3-Wire output must also match the receiving input. Wire it as a sourcing output and the input interface is wrong.

The cable and output still need drawings and limits

Wiring detail is thin, though cable leads establish the connection style. A wiring diagram, output load limit and mounting drawing are still needed to close the controller interface and mechanical clearance checks. None appears here.

View the Win-Source product page for E2EW-QX22C130 2M.

Key Takeaways for Engineers & Buyers

  • Match the machine supply to the 10V ~ 30V bounds.
  • Check target travel against the listed 22mm sensing distance.
  • Resolve the conflicting EU RoHS entries before releasing the BOM.