Omron E2EW-QX22C130 5M: Active, with a RoHS conflict to clear

E2EW-QX22C130 5M Omron product image

22mm sensing distance, 2Hz response and M30 threaded body; RoHS entries conflict.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status does not settle this sensor’s RoHS conflict

The RoHS record conflicts: one field says compliant, while the specification entry says non-compliant. The lifecycle signals agree on Active, so E2EW-QX22C130 5M remains a candidate for new design-in, but release must wait for an Omron declaration that settles EU RoHS. A sensor can fit the machine and still fail qualification on conflicting compliance records.

Will the M30 body and NPN-NO output fit the station?

Will it fit the existing station? The M30 threaded body needs a matching machine mount. It’s a cable-lead sensor, not a board-mounted part, and its NPN-NO, 3-Wire output needs a matching controller input. The listed 30V supply ceiling rules out a higher rail; the 10V lower boundary rules out a lower one.

Box describes the package, not mounting hardware. Order against the full threaded, cable-lead configuration: the abbreviated 22mm cylinder description identifies the sensor but does not settle how it mounts.

A 2Hz response ceiling limits moving-target work

2Hz is the listed response-frequency ceiling, not permission to count faster targets. A slow presence station may suit it; a faster conveyor cannot rely on this rating. The listed 22mm sensing distance is a reach limit, not a guaranteed actuation point for every target.

The 22mm reach still needs mounting and wiring evidence

Key details are missing. The 22mm reach has no sensing-distance test conditions, leaving the actuation point at the machine unresolved. M30 names the thread, but there is no dimensional drawing to establish mounting depth or clearance. NPN-NO, 3-Wire identifies the output arrangement, yet the wiring diagram and output load-current limit are absent; the description cannot settle cable termination or input loading.

Get the sensing-distance test conditions and dimensional drawing before freezing the station layout. Get the wiring diagram and output load-current limit before closing the controller connection. Those details determine whether the target trips where expected and whether the controller input can be driven without overstressing the output. For E2EW-QX22C130 5M, an incorrect lead connection or overloaded output is a plausible line-stop fault, not a detail to leave until installation.

View the Win-Source product page for E2EW-QX22C130 5M.

Key Takeaways for Engineers & Buyers

  • Resolve the opposing RoHS entries before approving the new BOM.
  • Check the 2Hz response ceiling against the station’s target rate.
  • Match the M30 thread and cable leads to the installed mount.