10V ~ 30V supply limits, 2mm sensing distance, M12 body; RoHS entries conflict.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
The supply range fits; the RoHS record does not
The 10V ~ 30V supply limits make E2EW-QX2B212 2M a new-design candidate only where the sensor rail stays inside that range; 30V is a ceiling, not a nominal setpoint. The lifecycle fields agree on Active status, so they give no reason to confine it to sustaining designs.
Material compliance is unresolved. The top-level field says RoHS Compliant, while the RoHS Status specification says RoHS Non-Compliant. That conflict can stop a controlled-material BOM even when the electrical fit is sound.
The 2mm reach leaves little room for mounting error
2mm is the listed sensing distance, not an installed gap allowance after tolerance buildup. Use it as the reach ceiling when placing the target. The 100Hz response-frequency ceiling also rules out assuming E2EW-QX2B212 2M will follow faster target events.
An M12 body helps placement, but the output must match
That tight gap puts the bracket under scrutiny. The shielded, threaded M12 cylinder can be positioned against a metal target, but the listing does not establish the clearance a particular mounting arrangement needs. The PNP-NC, 3-wire output belongs on an input designed for that polarity and normal state; treating it as normally open reverses the machine's indication.
Cable leads make this a wired installation rather than a plug-in connection. The stainless steel body and IP67 ingress rating suit an exposed machine position, but IP67 doesn't address chemical exposure. The listed 0°C ~ 85°C operating-temperature range bounds ambient selection; it does not establish how the cable behaves outside that range.
Cable leads need a wiring plan before release
The output load-current limit is missing, even though the termination and packaging entries are clear. Without that limit and an output wiring diagram, the controller connection can't be closed from this listing. A target-dependent sensing curve is also absent; it would settle how much margin the mounted target actually has.
Box is the stated packaging format; cable leads are the stated termination. Specify that termination in the build instructions, and resolve the conflicting EU RoHS entries before releasing the BOM.
View the Win-Source product page for E2EW-QX2B212 2M.
Key Takeaways for Engineers & Buyers
- Hold the 2mm target gap against mounting tolerances.
- Match the PNP-NC, 3-wire output to the controller input.
- Resolve the conflicting EU RoHS entries before BOM release.