2 mm inductive sensing, M12 threaded body, 10 V to 30 V supply range, 0°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
A 2 mm target gap puts mounting first
2 mm is the listed sensing distance. E2EW-QX2B212 5M is a new design-in candidate only where the metal target can pass close to the sensing face. That figure doesn't establish mounting tolerance or the effect of target material. The M12 threaded cylinder gives the bracket a defined mounting form, but a loose or variable target path needs more than the listed distance to make the fit credible.
Active status does not resolve the RoHS conflict
RoHS is the weak point: one field says RoHS Compliant, while another says RoHS Non-Compliant. The lifecycle fields agree on Active, with no listed lifecycle reason to restrict this part to sustaining designs. For a build requiring EU RoHS, get a manufacturer declaration tied to E2EW-QX2B212 5M before marking the BOM compliant.
The supply, temperature and response limits set different boundaries
10 V is the lower bound of the listed supply range. The 30 V figure is its upper ceiling, not a target rail; a machine supply outside that range rules out the electrical fit. The 0°C to 85°C operating-temperature range bounds where the sensor may be specified but says nothing about operation beyond either end.
The 100 Hz response-frequency rating needs to be checked against the machine's target rate, but it does not promise a clean transition at that rate for every target shape. The PNP-NC, 3-wire output must also match the controller input. An input expecting the opposite switching behavior turns a mechanical fit into a controls fault.
Cable leads make the connection plan the buying constraint
Cable-lead termination sets the connection constraint: E2EW-QX2B212 5M is not described with a plug, and Box denotes packaging, not another termination. Plan the cable route and field connection before approving it for the machine. An assembly built around a mating connector cannot use the M12 threaded body to resolve that mismatch. The stainless-steel body and IP67 rating describe the sensor enclosure, not how the field connection will be sealed.
The bracket and controller checks remain open
That leaves the mounting drawing, cable wiring diagram, target-material sensing curves and output load limit to get from the datasheet. Until then, bracket clearance and the controller connection remain open.
View the Win-Source product page for E2EW-QX2B212 5M.
Key Takeaways for Engineers & Buyers
- Set the target path against the listed 2 mm sensing distance.
- Check the controller input against the PNP-NC, 3-wire output.
- Resolve the conflicting RoHS entries before BOM release.