Omron E2EW-QX2B312 5M: Active, RoHS status unresolved

E2EW-QX2B312 5M Omron product image

2mm sensing limit, 10V ~ 30V supply range, M12 threaded body and 0°C ~ 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Close metal targets, not wide sensing gaps

Wide sensing gaps are the wrong job. E2EW-QX2B312 5M is a shielded inductive sensor for close metal targets on a machine; its Active lifecycle supports new design-in.

The 2mm limit sets the gap; 100Hz sets the event ceiling

2mm is the listed sensing-distance ceiling, not a promise that every metal target will switch at that gap. Leave the trip point open until the sensing conditions are known. The 100Hz response-frequency listing is also a ceiling: it screens out faster events, but without a response-time specification it cannot establish the switching delay. Get the gap wrong and the controller misses the target.

The 10V ~ 30V supply range sets the listed rail boundaries, not a preferred setpoint; a rail outside them rules the sensor out. Operating temperature is 0°C ~ 85°C, so a colder installation is outside the stated range. The threaded M12 cylinder needs a machine mounting point, while its cable leads need a wired controller input. Its PNP-NC/NO, 3-Wire output cannot simply replace a differently wired sensor.

Can the RoHS claim be signed off?

Is it RoHS compliant? The compliance field says RoHS Compliant, while the RoHS Status specification says RoHS Non-Compliant. Obtain a manufacturer declaration for E2EW-QX2B312 5M before releasing an EU RoHS-controlled build. The agreeing Active lifecycle entries can't settle a material declaration. The Box packaging entry does not change the cable-lead termination the assembly must accommodate.

M12 mounting and 3-Wire wiring still need detail

The 2mm sensing ceiling and 100Hz response ceiling leave position tolerance and event timing open. Sensing conditions for the target metal and a response-time specification are absent. A mechanical drawing is also absent, leaving mounting clearances unchecked; without a pinout, the PNP-NC/NO leads cannot yet be mapped to the controller input.

View the Win-Source product page for E2EW-QX2B312 5M.

Key Takeaways for Engineers & Buyers

  • Resolve the contradictory RoHS entries with a manufacturer declaration before EU RoHS release.
  • Check the 2mm sensing limit against the actual target and mounting gap.
  • Map the PNP-NC/NO, 3-Wire cable leads to the controller input using the missing pinout.