2mm sensing distance, 100Hz response, 10V ~ 30V supply; threaded M12 body with cable leads.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Active lifecycle does not settle the RoHS conflict
Can this sensor go into a new machine build? On lifecycle grounds, yes: E2EW-QX2C112 5M is marked Active across its status fields. That supports a new design-in. There’s no lifecycle reason for an existing production line to plan migration.
The compliance entries disagree. One says RoHS Compliant; another says RoHS Non-Compliant. Obtain a part-specific declaration before releasing a BOM that requires EU RoHS compliance. The conflict is a release issue, not evidence that the sensor has reached end of life.
The 2mm reach sets the installation, not just the sensor choice
2mm is the listed sensing distance. Target spacing is therefore the first constraint on the bracket and moving metal. That gap is small, and the listed reach does not establish detection of a variable target at that distance without checking its material and mounting geometry. The 100Hz response frequency limits the event rate this choice can support; it does not specify switching delay or the shortest detectable pulse.
The listed 10V ~ 30V supply limits bound the rail choice but say nothing about transient tolerance, while the 0°C ~ 85°C operating-temperature range bounds installation near hot equipment. Neither rating settles how the cable and output behave in the actual installation.
Not for long standoff or a sourcing input
Wrong for long-reach sensing or a controller input that expects a sourcing output, it suits a compact, shielded metal-target station. The threaded M12 stainless-steel body has an NPN-NO, 3-Wire output that needs a matching input. IP67 addresses ingress, not exposure of the cable to plant chemicals.
View the Win-Source product page for E2EW-QX2C112 5M.
The M12 thread still leaves mounting and wiring open
And that compact mounting makes the absent mechanical drawing consequential: the M12 thread alone cannot set the sensor’s installed position. The cable-lead wiring diagram and output load-current rating are also absent, so the NPN-NO label cannot close the input connection. Target-material correction curves are missing; they are needed to judge whether the listed 2mm sensing distance holds for the intended metal.
View the Win-Source product page for E2EW-QX2C112 5M.
Key Takeaways for Engineers & Buyers
- Set target spacing against the listed 2mm sensing distance.
- Check the required event rate against the 100Hz response frequency.
- Resolve the conflicting RoHS entries before release.