2mm sensing, 10V ~ 30V supply, M12 body; RoHS records disagree.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
The 2mm gap makes placement the first decision
A 2mm sensing distance puts target placement first. The lifecycle fields all mark E2EW-QX2C212 5M Active, making new design-in plausible, but its RoHS entries conflict. EU RoHS compliance remains unresolved.
The supply range cannot rescue a missed target
The narrow 2mm sensing distance is the weak point; the 10V ~ 30V supply range won't compensate for target motion or mounting tolerance that causes a missed detection. Keep the sensor rail within that range even during transients, and keep mounting points within the 0°C ~ 85°C operating range. The listed 100Hz response frequency provides a speed figure, but it does not establish whether a short target pass will be detected.
NPN-NC belongs at the right controller input
An input expecting a sourcing or normally open sensor is the wrong home for this part. Its output is NPN-NC, 3-Wire, so match it to a controller input wired for that logic. The threaded M12 cylinder gives the fixture a defined mounting format for positioning the inductive sensor at a metal target, while shielded construction matters where mounting space is tight; neither feature establishes the installed target position.
IP67 ingress protection and the stainless-steel body make a wet installation worth considering. Neither establishes how the cable-lead termination is protected at its far end. The LED can help during setup, but it cannot prove that target motion produces the intended controller signal throughout installed travel. Plan cable routing and termination with the fixture, not after panel wiring.
The M12 fixture still needs a drawing
And that fixture plan still needs a mounting drawing to establish thread and sensing-face geometry, plus a wiring diagram to identify lead functions before the NPN-NC input is wired. The output load-current rating is absent; document the match to the controller input and any interface load. Sensing-distance tolerance is absent too, so the listed 2mm distance is not a mechanical clearance guarantee.
Can the RoHS conflict hold the new-build BOM?
Will the RoHS conflict hold the new-build BOM? Yes. The compliance field says RoHS Compliant, while the specification says RoHS Non-Compliant; neither entry resolves the contradiction. Obtain a part-specific EU RoHS declaration for E2EW-QX2C212 5M and reconcile the entries before release. Listed box packaging doesn't change the wiring choice: the installation still has to accommodate cable leads.
View the Win-Source product page for E2EW-QX2C212 5M.
Key Takeaways for Engineers & Buyers
- Hold E2EW-QX2C212 5M BOM release until the conflicting EU RoHS entries are reconciled.
- Check the 2mm target gap against installed motion and tolerance.
- Match the NPN-NC, 3-Wire output to the controller input.