5mm sensing distance, 10V ~ 30V supply, M18 threaded body, 0°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V |
The 5mm pickup is a new-design candidate, with one hold
5mm is the listed sensing distance. It isn’t permission to place a target at that edge without accounting for mounting tolerance. Omron E2EW-QX5B318 2M is a reasonable new-design candidate where a shielded inductive sensor can sit in an M18 threaded mount and detect a nearby target. Lifecycle Status and Product Status both read Active. Active is not the hold. The conflicting RoHS entries prevent a controlled BOM from treating the part as cleared.
Supply bounds and 80Hz limit the electrical fit
The 10V ~ 30V supply range and 80Hz response-frequency ceiling bound the electrical fit. A rail beyond those supply bounds is outside the listed range. The 80Hz figure does not promise that every target event will register at the controller input, and the supply range gives no allowable output load.
An M18 mount still needs a wiring and clearance check
Nor does electrical fit settle the mounting. The M18 threaded cylinder and cable leads suit a mounted pickup, but without a dimensioned drawing or cable-lead assignment, the mounting layout and wiring schematic remain open. The PNP-NC/NO, 3-Wire output must match the input circuit.
The 0°C ~ 85°C operating-temperature range excludes colder installations; it does not establish how sensing distance changes with temperature. IP67 and a stainless-steel body do not, by themselves, establish resistance to the chemicals used around a machine. An output load limit and target-dependent sensing-distance information are also missing. Those gaps matter before the enclosure and controller input are committed.
Active status does not settle the RoHS conflict
Can this part go on the BOM? The compliance field calls E2EW-QX5B318 2M RoHS Compliant, while the specifications call it RoHS Non-Compliant. Neither entry can safely override the other; obtain a part-specific EU RoHS declaration before release. The aligned Active signals support planning a new design-in, but they cannot resolve this purchase constraint.
View the Win-Source product page for E2EW-QX5B318 2M.
Key Takeaways for Engineers & Buyers
- Set target placement against the listed 5mm sensing distance.
- Match the input circuit to the PNP-NC/NO, 3-Wire output.
- Resolve the contradictory RoHS statuses before BOM release.