5mm sensing, 10V–30V supply, M18 threaded body; RoHS entries disagree.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V |
5mm reach sets the target geometry
5mm is the listed sensing-distance ceiling; place the target with its actual travel and mounting tolerances in mind, because reliable detection at the edge of that distance isn't established. The shielded stainless-steel M18 threaded body suits a mounted industrial sensing point, but thread size alone does not settle bracket fit.
The listed 10V to 30V supply window sets the electrical boundaries, with 30V as a ceiling rather than a working setpoint. It does not establish tolerance to supply transients. The 0°C to 85°C operating-temperature range rules out installations expected to fall below its lower boundary.
80Hz and NPN output narrow the machine fit
Fast-moving targets aren't the job to assume here. The 80Hz response-frequency ceiling alone cannot establish whether the shortest target event will register. A slower-position detection point is more plausible, provided its timing is checked against the machine cycle.
The 3-wire NPN-NC/NO output must match the controller input and the required contact behavior. A mismatch may produce the opposite state or leave the sensor unrecognized. IP67 describes the listed ingress protection; cable routing and installation still matter.
Active status does not settle the RoHS dispute
Can this sensor go on a new machine BOM? E2EW-QX5C318 2M has aligned Active lifecycle signals, so lifecycle status does not bar new design-in. EU RoHS is the hold: one entry says compliant and another says non-compliant. Neither settles a restricted build.
Resolve the conflict with an Omron compliance statement before release. Box packaging and cable-lead termination are listed, but the leads still need a connection plan on the line.
The M18 installation still needs its drawing
Mechanical fit remains open. The datasheet must supply the cable-lead pinout, M18 mounting drawing, and output load limit before the wiring and bracket details can be settled.
View the Win-Source product page for E2EW-QX5C318 2M.
Key Takeaways for Engineers & Buyers
- Check target travel against the 5mm sensing-distance ceiling.
- Match the 3-wire NPN-NC/NO output to the controller input.
- Resolve the contradictory EU RoHS entries before a restricted release.