10mm sensing ceiling, 10V ~ 30V supply bounds, M30 threaded body, 0°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 40Hz; Voltage - Supply: 10V ~ 30V |
Active status clears one gate, but RoHS blocks release
The 10mm sensing ceiling calls for target testing; conflicting RoHS entries stop release. E2EW-X10B130 5M is marked Active throughout its lifecycle entries, so lifecycle status supports a new design-in. That isn't compliance clearance. One field says RoHS Compliant; the specifications say RoHS Non-Compliant. Compliance remains unresolved, not established as non-compliant. Resolve the contradiction before BOM release.
The sensing limit matters more than the supply range
The 40Hz response-frequency ceiling is the weak point for fast-moving targets. It is not a response-time specification, and a passing target that demands faster detection can go unseen. The 10mm sensing distance is also a ceiling, not a promise of detection at that spacing with every metal target. Bench-test the intended target at the proposed gap before fixing the sensor position, because a mechanically sound installation can still miss parts when the 10mm ceiling is treated as a guaranteed detection distance.
The listed 10V ~ 30V supply bounds rule out rails outside that range. They do not establish output loading or behavior during a supply dip. A PNP-NO, 3-Wire output belongs on an input arranged for that signal, not one expecting a normally closed contact. Those electrical checks are straightforward; target detection is harder to recover from after the bracket is built.
The temperature range excludes freezing installations
0°C ~ 85°C is the listed operating-temperature range. An installation expected to fall below 0°C is outside it, regardless of the stainless-steel body or IP67 ingress rating. Keep E2EW-X10B130 5M out of that location.
M30 mounting needs a drawing before the bracket is cut
M30 identifies a threaded cylinder, not a complete bracket drawing. The sensor has cable leads and comes in a box, so plan a cable route rather than a mating connector. The mounting drawing and wiring diagram are absent; obtain both before cutting the bracket or assigning the PNP-NO input. A target-dependent sensing curve is absent too; it would help establish how much of the 10mm ceiling the installation can use.
View the Win-Source product page for E2EW-X10B130 5M.
Key Takeaways for Engineers & Buyers
- Test the intended target within the 10mm sensing ceiling.
- Check event frequency against the 40Hz response-frequency ceiling.
- Resolve the conflicting RoHS entries before BOM release.