10mm sensing distance, 2Hz response, 10V ~ 30V supply bounds, threaded M18 body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
2Hz rules out fast counts before M18 fit matters
Fast machine counts aren't its job. The listed 2Hz response frequency limits the detection rate but doesn't specify switching delay. A slow metal-presence check at a fixed machine position makes more sense, though the shielded inductive head's 10mm sensing distance alone cannot establish clearance for every target or mounting condition.
The threaded M18 body suits a matching machine mount. Its PNP-NO, 3-Wire output requires the corresponding controller input, while the listed 10V ~ 30V supply bounds settle the rail choice without establishing tolerance of excursions outside them. Operating temperature runs from 0°C to an 85°C ceiling; a machine exposed to temperatures below 0°C is outside the stated range.
Active status cannot clear the RoHS contradiction
Design-in remains conditional. E2EW-X10B1T18 5M has aligned Active lifecycle entries; lifecycle alone does not confine it to sustaining designs. One field says RoHS Compliant, while another says RoHS Non-Compliant. Resolve the conflict before approving the part for an EU RoHS build.
What the 10mm rating leaves unanswered
That still leaves the installed detection gap unsettled, even after compliance is resolved: the 10mm sensing distance needs a target-material curve before it can set that gap. The listing also lacks a switching waveform for interpreting the 2Hz response in a timed sequence, a cable-lead wiring diagram for connection, and a mechanical drawing for the M18 installation. Those gaps leave the installation unsettled.
Cable leads make the purchase specification matter
Will the line receive the cable-lead M18 version it is built to install? The listed termination is cable leads and the package is a box; neither describes a connector that could be fitted in its place. Put the cable-lead termination and threaded M18 body on the purchase specification so a different physical configuration does not stop assembly.
View the Win-Source product page for E2EW-X10B1T18 5M.
Key Takeaways for Engineers & Buyers
- Match the controller input to PNP-NO, 3-Wire output and the 10V ~ 30V supply bounds.
- Keep machine counts within the listed 2Hz response frequency.
- Resolve the conflicting RoHS entries before clearing the part for production.