Omron E2EW-X10B218 5M: Active, with RoHS status unresolved

E2EW-X10B218 5M Omron product image

10V ~ 30V supply, 10mm sensing, M18 threaded body; 0°C ~ 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

The supply and temperature ranges set the installation boundary

10V ~ 30V is the supply range at the sensor. It doesn't settle how a transient at the cable end affects that margin. The 0°C ~ 85°C operating range excludes colder mounting locations; 85°C is a ceiling, not a target.

Active status supports design-in, but RoHS is unresolved

Design-in is defensible. All listed lifecycle entries agree on Active, so lifecycle status does not confine the sensor to sustaining use. RoHS is the snag: the compliance field says EU RoHS compliant, while the specification entry says RoHS Non-Compliant. That conflict is unresolved, not proof of noncompliance. Settle it before committing the part to a build requiring EU RoHS compliance.

The 2Hz ceiling rules out fast target streams

Fast target streams are the wrong job. The listed 2Hz response-frequency ceiling rules out streams needing faster detection; a good mechanical fit will not make missed events acceptable. For slower presence detection, the 10mm sensing distance is a reach to assess against the target and mounting arrangement, not clearance to spend as spare travel.

The M18 threaded cylinder and cable leads belong on a fixed machine bracket, not a connectorized sensor port. Match the PNP-NC, 3-Wire output to the input circuit's expected signal and wiring, or the machine can read the wrong state even when sensing works. The stainless-steel body and IP67 rating describe construction and ingress protection. Neither changes the 2Hz ceiling.

Cable leads leave wiring and mounting details to close

That bracket choice leaves termination to plan: the Box-packaged sensor has cable leads, not a plug-in harness. Get the pinout, dimensional drawing, and output load-current limit before releasing the bracket and input wiring. None is listed here, leaving mechanical clearance and electrical load open.

View the Win-Source product page for E2EW-X10B218 5M.

Key Takeaways for Engineers & Buyers

  • Keep the sensor supply within the listed 10V ~ 30V range.
  • Check whether the intended event rate fits the 2Hz response-frequency ceiling.
  • Resolve the conflicting EU RoHS entries before releasing E2EW-X10B218 5M.