10mm sensing distance, 10V to 30V supply, M30 body and 0°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 40Hz; Voltage - Supply: 10V ~ 30V |
Active status clears the lifecycle question, not the RoHS conflict
Can this go on a new machine BOM? Every lifecycle field lists E2EW-X10B230 2M as Active, so new design-in is reasonable. But one EU RoHS field says compliant and another says non-compliant. Get a definitive manufacturer declaration before release.
The 10mm reach still needs a target check
10mm is the listed sensing distance, not a guaranteed trip point at that spacing. Without the reference target and mounting conditions, that figure can't establish where the intended target will trip, even if the controller rail falls within the 10V to 30V supply range. Those supply boundaries don't establish immunity to excursions. The 0°C to 85°C operating-temperature range rules out a colder location but says nothing about heat conducted into the sensor from nearby machinery.
The threaded body does not settle mounting or wiring
The missing wiring diagram is a weak point, as are the mounting drawing and sensing-distance target conditions. PNP-NC, 3-Wire output and cable leads still identify the controller input architecture to plan. Until the datasheet supplies those missing details, the threaded body alone cannot settle mounting depth or prove detection of the intended target.
A 40Hz sensor belongs on the right machine cycle
A controller wired for an NPN input, or a machine cycle needing detection beyond the listed 40Hz response frequency, is the wrong destination. That frequency does not establish pulse timing for a particular installation. This inductive sensor belongs at a metal-detection point where the M30 threaded cylinder fits the bracket and cable leads suit the harness.
IP67 supports the ingress-protection choice, not a claim of chemical resistance; the stainless-steel body does not close that question. The LED gives a technician local indication when chasing a missed count, but cannot diagnose controller wiring. Set the input polarity before committing the harness.
View the Win-Source product page for E2EW-X10B230 2M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting RoHS fields for E2EW-X10B230 2M before release.
- Check the 10V to 30V supply boundaries against the controller rail.
- Match the listed 40Hz response frequency to the machine cycle.