Omron E2EW-X10B3D18 2M: Active, RoHS status disputed

E2EW-X10B3D18 2M Omron product image

10mm sensing distance, 2Hz response ceiling, threaded M18 body and 0°C to 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status does not settle the RoHS conflict

The RoHS record conflicts, but every lifecycle signal marks E2EW-X10B3D18 2M Active. The compliance field says compliant; the specification says non-compliant. That conflict can stop a controlled BOM. Obtain a part-specific RoHS declaration before committing the sensor to a build.

There is no lifecycle disagreement to resolve. Low lifecycle risk supports considering the part for new work, but it says nothing about the disputed material status or whether the sensing and mounting limits fit the machine. This is a candidate for new design-in, not an automatic release. Keep the decisions separate: settle the RoHS conflict before BOM release, then judge the installation against the sensor’s limits.

The 2Hz ceiling rules out fast target changes

Fast target changes aren't supported. The listed 2Hz response frequency is a ceiling, not a switching-time specification; it cannot justify a faster sequence of targets. The listed 10mm sensing distance caps the assumed trigger gap, so the rating does not support a fixture needing more separation.

The 10V to 30V supply limits bracket the rail. Treat 30V as a ceiling, not a setpoint, and do not assume operation outside either boundary. These numbers help establish whether the controller supply and target spacing are plausible. They do not establish switching latency or installed detection margin.

M18 mounting fits a fixed machine position

An installation below 0°C is wrong for this sensor; its listed operating range is 0°C to 85°C. The shielded, threaded M18 cylinder fits a fixed machine position where a target approaches the sensing face and the cable leads route back to the controller. IP67 is the listed ingress rating, not a rating for an unprotected cable termination.

The PNP-NC/NO, 3-Wire output needs a compatible controller input. Fitting the M18 body will not make another output type compatible.

M18 threads do not close the installation details

10mm is the listed sensing distance, but it does not supply the missing sensing-distance-versus-target-material curve. M18 identifies the thread; without a mounting drawing, it does not establish the full installed envelope. A wiring diagram is also absent for the PNP-NC/NO, 3-Wire connection. Obtain the missing output load-current rating and sensing-distance-versus-target-material curve before fixing the controller input and target position.

Will the line receive cable leads?

Are cable leads the specified termination? The listing says cable leads and gives the package as Box. Put that termination on the purchase order and match the assembly instructions to it; M18 mounting does not settle how the leads connect at the machine.

View the Win-Source product page for E2EW-X10B3D18 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting RoHS entries before releasing E2EW-X10B3D18 2M on a controlled BOM.
  • Keep target changes within the listed 2Hz response-frequency ceiling.
  • Check the controller input against the PNP-NC/NO, 3-Wire output.