Omron E2EW-X10C118 2M: Active, but RoHS status conflicts

E2EW-X10C118 2M Omron product image

2Hz response, 10mm listed sensing distance, M18 body; supply limits of 10V to 30V.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

The 2Hz response sets the sensing job

The 2Hz response frequency sets the pace: this is a candidate where metal presence changes slowly enough for that response. The listed 10mm sensing distance is a reach ceiling, not a promise of detection with every target at that spacing, and target-dependent sensing conditions are not stated.

The NPN-NO, 3-Wire output also has to suit the input circuit. Moving the sensor won’t fix an incompatible input. E2EW-X10C118 2M is marked Active across the lifecycle signals, making it suitable for consideration in a new design-in if the sensing fit works. RoHS status is unresolved: one field says compliant and another says non-compliant. Resolve that conflict before release.

The supply bounds do not settle installation conditions

10V to 30V are the listed supply bounds, not suggested setpoints. A rail outside them rules out the sensor; a rail inside them does not settle its behaviour during supply transients. The stated 0°C to 85°C operating temperature range likewise rules out an installation below or above those bounds. These are the first electrical and ambient checks, not a description of the complete installation.

Will cable leads fit the line build?

Will cable leads work on this line? E2EW-X10C118 2M is packaged as Box and terminates in cable leads. Put cable termination in the build instructions rather than assuming a mating connector.

The M18 thread decides the mounting fit

A mount that cannot accept an M18 threaded cylinder rules this out. Where the thread fits, the shielded inductive construction and stainless-steel body give the installer a defined mechanical starting point. IP67 states the sensor’s ingress protection; it does not establish how the cable entry will be sealed in the finished machine.

The drawing and pinout still have to close the fit

Even with the thread matched, a mechanical drawing must fix the cutout and clearances. The pinout is absent, so the cable wiring cannot be released from the NPN-NO, 3-Wire label alone. Response-frequency test conditions are also absent; 2Hz by itself does not establish the required target dwell time.

View the Win-Source product page for E2EW-X10C118 2M.

Key Takeaways for Engineers & Buyers

  • Check target timing against the 2Hz response frequency.
  • Resolve the conflicting RoHS entries before releasing E2EW-X10C118 2M.
  • Match the M18 thread to the fixture.