10mm sensing, 2Hz response, M18 threaded body; check input polarity and RoHS status.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in; RoHS still needs an answer
And that leaves compliance as the obstacle: all listed lifecycle signals say Active, making E2EW-X10C118 5M a candidate for new design-in rather than a sustaining-only choice. One RoHS field says compliant; the specification says non-compliant. EU RoHS status remains unresolved. Don't release it on an EU RoHS-controlled BOM until Omron resolves the conflict.
What reaches the assembly bench?
Will it arrive ready to plug in? No plug-in connection is specified: box packaging and cable leads leave termination to the assembly process. Plan cable routing and lead termination before fixing the sensor location. Active status supports the purchase decision, but installation work remains.
A slow metal-presence check fits better than rapid counting
Rapid counting is the wrong job. The listed 2Hz response frequency limits event detection; performance for faster-arriving targets is not established. A slow metal-presence check is a better fit, though the 10mm sensing distance is listed reach, not guaranteed clearance for every target geometry.
Its shielded M18 threaded cylinder belongs at a machine-mounted sensing point with room to fasten the body and route the cable, rather than in a layout built for an unthreaded sensor or plug-in termination. The NPN-NO, 3-Wire output must also match the control input's expected switching polarity. A mismatch can leave the input in the wrong state even after the sensor is installed.
The supply and temperature boundaries are firm
Voltage and temperature limits narrow the installation envelope. The 10V ~ 30V supply range sets both boundaries: 30V is the upper operating limit, not allowance for excursions above it, and operation below 10V is not established. The 0°C ~ 85°C operating range rules out an installation expected to cross either temperature boundary at the sensor. IP67 addresses ingress protection; it does not extend the temperature range.
3-Wire still leaves the hookup unresolved
3-Wire doesn't identify lead assignments. Without a wiring diagram or output load-current limit, the control-input hookup and output loading remain unresolved. Sensing-distance test conditions are also absent, so the 10mm figure alone cannot settle target clearance.
View the Win-Source product page for E2EW-X10C118 5M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting EU RoHS entries before releasing a controlled BOM.
- Check whether the 2Hz response frequency covers the target event rate.
- Match the NPN-NO, 3-Wire output to the control input.