10mm sensing, 10V ~ 30V supply, M30 body; 40Hz response needs a motion check.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 40Hz; Voltage - Supply: 10V ~ 30V |
Active status clears the lifecycle question, not the RoHS conflict
Can this Active inductive sensor go into a new machine BOM? Active lifecycle signals support a new design-in for E2EW-X10C230 2M, whose threaded M30 body and cable leads suit a machine-mounted sensing point. That is not a release decision. The compliance field says RoHS Compliant, while the specifications say RoHS Non-Compliant. Treat EU RoHS status as unresolved until those entries are reconciled.
The 10mm target gap has to work in an M30 mounting
10mm is the listed sensing distance, not proof that every target will be detected at that gap. Check the actual target and mounting position before committing the bracket. The shielded, threaded M30 body gives the mechanical concept a starting point.
The listed 10V ~ 30V supply range bounds the electrical choice; it does not establish the voltage at the sensor after cable losses. The 0°C ~ 85°C operating range rules out an installation that must sense below 0°C. An NPN-NC, 3-Wire output requires a compatible controller input: detection is no use if that input expects the opposite switching state.
The 40Hz response leaves fast targets unproven
Target speed runs into a 40Hz response constraint. Compare that figure with the target's passage rate; no switching waveform is listed to show whether a brief encounter produces a usable controller signal. Don't sign off a fast-moving target from sensing distance alone.
Close the wiring and sensing gaps before releasing the BOM
Nor does that speed check settle the wiring or mechanical fit. No sensing-distance test conditions, output load-current limit, cable wiring diagram or dimensioned drawing are listed. Those gaps leave the target choice, controller load and M30 installation short of a final check; the LED indicator can't settle them.
The immediate buying constraint is the contradictory RoHS status, not the Active lifecycle. Get a written resolution of the opposing EU RoHS entries for E2EW-X10C230 2M before releasing the BOM.
View the Win-Source product page for E2EW-X10C230 2M.
Key Takeaways for Engineers & Buyers
- Check the 10mm sensing distance against the actual target and mounting position.
- Compare the 40Hz response frequency with the target's passage rate.
- Resolve the conflicting EU RoHS entries before BOM release.