Omron E2EW-X12B1D18 2M: active, with RoHS unresolved

E2EW-X12B1D18 2M Omron product image

12mm sensing ceiling, 2Hz response ceiling, M18 threaded body; 10V ~ 30V listed supply bounds.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 12MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

12mm reach makes this a close-range design-in

12mm is the listed sensing-distance ceiling, not a detection guarantee for every target. E2EW-X12B1D18 2M fits a close-range inductive sensing position where target and mounting geometry can be checked against that reach. Its Active status supports new design-in on lifecycle grounds, but EU RoHS-dependent release remains on hold: the compliance field says compliant, while the specification says non-compliant. Neither entry resolves the other.

A 2Hz ceiling rules out fast event counting

Speed is the weak point: the 2Hz response-frequency ceiling limits moving-target applications. The listed 10V ~ 30V supply bounds and PNP-NO, 3-Wire output give a controller designer a definite interface to screen. Neither voltage endpoint is a preferred setpoint; keep the rail within those bounds. If the machine needs events resolved faster than the listed frequency allows, an electrical match won't rescue the application.

M18 mounting suits a protected sensor position

That electrical fit still leaves the physical installation to consider. The shielded, stainless-steel M18 threaded body can sit at a machine sensing point, with cable leads routed back to the controller. IP67 is the listed ingress protection, not a reason to ignore cable installation. The operating-temperature range is 0°C ~ 85°C, so a position that must operate below 0°C falls outside it. The LED provides local indication during setup.

The 12mm and 2Hz figures leave critical tests open

Reach and speed require separate checks. No sensing-distance test target is listed, so a fixture set at the 12mm ceiling could still miss the production target. The 2Hz frequency ceiling can't substitute for an absent response-time specification when edge timing matters. Passing the target check does not settle timing.

Get the cable-lead pinout before releasing the harness and the M18 mechanical drawing before machining the bracket; neither item is present here, so E2EW-X12B1D18 2M can screen the concept but cannot settle wiring or mounting details.

Cable leads commit the assembly process

Cable leads change assembly. Plan a harness termination step rather than connector mating for the box-packed build, and resolve the RoHS conflict before releasing an EU RoHS-dependent line.

View the Win-Source product page for E2EW-X12B1D18 2M.

Key Takeaways for Engineers & Buyers

  • Keep the supply rail within the listed 10V ~ 30V bounds.
  • Screen event rates against the 2Hz response-frequency ceiling.
  • Resolve the conflicting RoHS entries before approving an EU RoHS-dependent build.