Omron E2EW-X12B1T18 5M: Active, but conditional design-in

E2EW-X12B1T18 5M Omron product image

12mm sensing distance, 2Hz response ceiling, M18 threaded body and 10V ~ 30V supply range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 12MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

The 12mm distance is a screen, not a detection guarantee

12mm is the listed sensing distance, not a guarantee that every metal target will switch at that gap. It can rule out installations that need more reach; target-dependent sensing data must settle the actual mounting gap.

E2EW-X12B1T18 5M is marked Active across the lifecycle fields, so lifecycle status does not block new design-in. Compliance does: one field says RoHS Compliant and another says RoHS Non-Compliant. Resolve the conflict before releasing a BOM that requires EU RoHS.

The supply and ambient ranges bound the installation

Power and ambient limits bound the installation. The listed supply operating range is 10V ~ 30V; a supply outside it rules this sensor out. That range says nothing about what load the output can drive.

The operating-temperature range is 0°C ~ 85°C. An installation outside either boundary needs a different answer, not an assumption that the stainless-steel body extends the electrical rating. Neither 30V nor 85°C is a preferred setpoint.

A 2Hz ceiling rules out fast detection

Fast part counting is the wrong job for a listed 2Hz response-frequency ceiling. Don't assume faster transitions will be caught. Slower metal-presence checks are more credible when the machine accepts a shielded, M18 threaded cylinder and its input expects a PNP-NO, 3-wire output.

The IP67 rating and stainless-steel body make exposed industrial mounting worth considering, but neither establishes resistance to a particular cleaning chemical. The threaded body needs a fixture location, not a place on a circuit board.

Can the line terminate cable leads consistently?

Will the line terminate cable leads consistently? That is the practical buying question for E2EW-X12B1T18 5M. The part is packaged in a box, but the installation work is at the cable end: the line needs a repeatable way to route and terminate the leads at the intended PNP-NO, 3-wire input. If the existing assembly expects a plug-in sensor, the listed termination does not establish a match. Set the termination method in the build instructions before committing the fixture to this part.

For existing production, keep the exact part identifier tied to the assembly instructions because a mechanically fitting M18 cylinder with the wrong output connection can stop a line even when it threads into the mount. Active lifecycle status removes an end-of-life objection. It does not resolve the connection.

The missing load and mounting details still matter

Output-load current is missing, though the PNP-NO designation identifies the output to match to an input load. Target-dependent sensing data is also absent, along with a wiring diagram and mounting drawing. Those details would settle the detection gap and physical installation.

View the Win-Source product page for E2EW-X12B1T18 5M.

Key Takeaways for Engineers & Buyers

  • Treat 12mm as the listed sensing-distance limit; get target-dependent sensing data.
  • Screen the event rate against the 2Hz response-frequency ceiling.
  • Resolve the conflicting EU RoHS entries before BOM release.