2Hz response ceiling, 12mm sensing reach, M18 threaded body; RoHS entries disagree.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 12MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
The 2Hz ceiling decides what this sensor can count
A 2Hz ceiling rules out fast counting. The 12mm figure gives a reach to check against target travel, not a guaranteed switching point for every target, so bracket placement still has to account for detection.
The 10V ~ 30V supply limits let you screen the control rail. They do not establish how much load the PNP output can drive.
Active lifecycle does not settle the RoHS conflict
Compliance is the weak point: the compliance field says RoHS Compliant, while the specifications say RoHS Non-Compliant. Obtain a part-specific declaration from Omron before EU RoHS signoff.
The lifecycle signals all say Active, making E2EW-X12B3D18 2M a new design-in candidate rather than a sustaining-only part. For a running line, resolve the RoHS conflict before approving it on a controlled BOM.
An M18 bracket fits; a fast counter does not
RoHS clearance won't make this a universal proximity switch. Its shielded inductive head sits in an M18 threaded stainless-steel cylinder, suited to a machine bracket facing a metal target. Target travel must stay within the listed 12mm sensing-distance ceiling, though that ceiling does not guarantee switching at 12mm for every target. It is not a PCB-mounted sensor. The cable leads need a route out of the bracket, and the PNP-NC/NO, 3-Wire output needs a compatible controller input; moving the sensor cannot fix an input-type mismatch.
The stated 0°C ~ 85°C operating range excludes locations below 0°C. IP67 addresses ingress protection, not chemical exposure. The LED can help locate the sensor’s indication at the machine, but it does not establish that the controller registered an event.
M18 is not enough to release the bracket
M18 gives the thread size, not the dimensional drawing needed for bracket clearance. The cable pinout is absent, so wiring cannot be released. The missing output-current limit and target-dependent sensing curve leave controller loading and switch position unresolved.
View the Win-Source product page for E2EW-X12B3D18 2M.
Key Takeaways for Engineers & Buyers
- Keep event rates within the 2Hz response ceiling; rule out fast counting.
- Allow for the M18 threaded body and a route for its cable leads.
- Flag the conflicting RoHS entries on the controlled BOM.