Omron E2EW-X12B3T18 5M: Active, with RoHS conflict

E2EW-X12B3T18 5M Omron product image

2Hz response, 12mm sensing limit, M18 threaded body, and 0°C to 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 12MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Is 2Hz enough for this inductive sensor?

2Hz is the listed response frequency. Rapid target transitions are a poor match. E2EW-X12B3T18 5M is Active across the lifecycle fields, so new design-in is reasonable where that response fits the machine cycle. EU RoHS status remains unresolved: the compliance field says compliant, but the specification list says non-compliant. Reconcile that conflict before a compliance-dependent release.

The 12mm reach does not settle target detection

Even at that pace, the 12mm sensing distance remains a listed reach limit, not proof that every metal target will trip at that separation in the intended mounting geometry. The 10V to 30V supply range defines the rail choice. Treat 30V as the upper limit, not a preferred operating point; a rail outside the listed range is not supported here.

The 0°C to 85°C operating-temperature range rules out a location beyond either bound. IP67 does not widen that range. The PNP-NC/NO, 3-Wire output calls for a compatible input and wiring arrangement, but no permissible output load is listed. Without that rating, the output connection remains unsettled.

The M18 mount makes cable leads a buying decision

The M18 mount and cable leads constrain the purchase. E2EW-X12B3T18 5M comes in a box with cable leads. Put the required field termination on the BOM; don't assume a connector is supplied.

Where the IP67 body fits—and what the drawing must settle

A connector-ready retrofit is wrong for cable leads. The shielded stainless-steel M18 body with IP67 protection instead fits a threaded industrial mounting point where that termination is planned.

The datasheet still needs to supply a mounting drawing for clearances and a wiring diagram for the PNP-NC/NO connections. A target-dependent sensing curve is also absent, leaving the listed 12mm reach unproven for the actual target and mounting geometry.

View the Win-Source product page for E2EW-X12B3T18 5M.

Key Takeaways for Engineers & Buyers

  • Match the 2Hz response frequency to the target event rate.
  • Resolve the conflicting RoHS entries before compliance-dependent release.
  • Specify the M18 mount and cable-lead termination on the BOM.