10V ~ 30V supply limits, 12mm sensing distance and a threaded M18 body set the first fit checks.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 12MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in, but RoHS does not clear
New design-in is defensible. The lifecycle signals agree on Active status, but the RoHS entries conflict: the compliance field says compliant, while the specification says non-compliant.
NPN-NC output decides the controller fit
A controller expecting different output polarity is the wrong partner: the listed NPN-NC, 3-Wire interface could leave its detection state inverted. For a threaded machine mount, the shielded M18 cylinder and stainless-steel body make physical sense. Cable leads determine how the connection reaches the controller. IP67 describes ingress protection at the sensor, not the cable-entry installation. The LED offers local indication, not proof that the controller interprets the signal correctly.
The sensing and response limits decide whether targets register
But fit isn't detection. The listed 12mm sensing distance is a ceiling, not a guaranteed trip point for every metal target or mounting arrangement. Set the proposed target gap against that limit; choosing 12mm as the installation gap leaves no basis here for target or mounting variation. The 2Hz response-frequency ceiling matters too: faster target streams risk missed events, and the figure doesn't specify switching delay.
Although the 10V ~ 30V supply limits bound the rail choice, they say nothing about the output-current limit or the controller input, so rail compatibility alone cannot establish detection performance. Operating temperature is listed as 0°C ~ 85°C. An installation outside those bounds has no temperature basis here; IP67 does not extend the range.
Cable leads and missing drawings hold up release
Will the cable leads suit the machine's termination scheme? Box packaging does not answer that; settle the termination layout before committing E2EW-X12C218 5M to an existing line.
The datasheet still needs to supply a wiring diagram, output-current limit, sensing-distance target correction curve and mounting drawing. Without them, the M18 thread and stated sensing distance do not amount to an installation plan. Obtain a manufacturer RoHS declaration to settle the conflicting entries before BOM release.
View the Win-Source product page for E2EW-X12C218 5M.
Key Takeaways for Engineers & Buyers
- Compare the 2Hz ceiling with the fastest target rate.
- Keep the proposed supply within the 10V ~ 30V limits.
- Resolve the conflicting RoHS entries before BOM release.