20mm sensing distance, 10V to 30V supply limits, M30 thread, and 0°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in; the RoHS record does not
The RoHS record is the weak point: its compliance field says RoHS Compliant, but its specification says RoHS Non-Compliant. Every lifecycle signal marks the Omron E2EW-X20B1T30 2M Active, so it's a new design-in candidate for industrial metal detection, but a build requiring confirmed EU RoHS cannot clear it until the conflict is resolved.
A shielded, stainless-steel M30 body with an IP67 designation suits a threaded machine mount exposed to dust and water; neither establishes how the cable exit will fare in the actual installation. Check the cable exit at the mount. The PNP-NO, 3-wire output needs a compatible input. If the input is incompatible, that calls for a wiring change, not a purchasing substitution.
The 20mm distance is not installed clearance
20mm is the listed sensing-distance ceiling, not guaranteed clearance for every target. If target position can wander, establish the trip point from the target-specific sensing curve and hysteresis; neither is listed. A gap set at 20mm has no demonstrated detection margin.
Supply limits and response rate decide different failures
10V to 30V sets the supply limits, not a preferred operating rail. A supply outside that window falls outside the stated electrical range. The listed 2Hz response frequency matters when metal passes the face rather than resting there, but no timing definition is given to establish a guaranteed detection interval. The 0°C to 85°C operating-temperature range does not support signing off a colder installation, regardless of the IP67 designation.
The M30 mount and cable leads control a running-line change
M30 mount and cable-lead compatibility govern a running-line changeover. Match the mount and termination to the existing installation rather than treating a connector-bodied sensor as interchangeable. E2EW-X20B1T30 2M is listed in a box; put the cable-lead termination explicitly on the BOM for existing production.
The mounting drawing is absent, so the thread alone cannot settle the installed envelope. Conductor assignments and an output-current limit are also absent; those details are needed to close the wiring and input-load checks.
View the Win-Source product page for E2EW-X20B1T30 2M.
Key Takeaways for Engineers & Buyers
- Set the trip point against the actual target; 20mm is not guaranteed installed clearance.
- Resolve the conflicting RoHS entries before releasing a compliant build.
- Test passing targets at the required machine speed against the listed 2Hz response frequency.