Omron E2EW-X20B3D30 2M: Conditional new design-in

E2EW-X20B3D30 2M Omron product image

2Hz response ceiling, 10V ~ 30V supply limits and an M30 threaded body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 20MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status cannot settle the RoHS conflict

Conflicting RoHS entries block an unconditional design-in: the compliance field says RoHS Compliant, while the specifications say RoHS Non-Compliant. The lifecycle signals agree on Active, making E2EW-X20B3D30 2M a candidate for new equipment rather than a sustaining-only part. Settle its EU RoHS status before releasing a restricted-material BOM. The conflict says nothing about whether the sensor will switch correctly.

The 2Hz ceiling limits what this sensor can count

2Hz is the listed response-frequency ceiling. It suits slow presence checks, not fast part counting, and does not establish a complete switching-time profile. The 10V ~ 30V supply range puts 10V at the lower limit and 30V at the upper; it screens the rail without establishing transient tolerance. The 0°C ~ 85°C operating range provides no specified operating claim below 0°C, despite the stainless-steel body and IP67 rating.

The M30 body needs room; the cable leads need a plan

A panel without room for an M30 threaded cylinder is the wrong home for this sensor. A machine with a compatible mount and a target within the listed 20mm sensing distance is a plausible fit, but that distance alone doesn't establish the trip point for the intended target. Shielding is listed. Mounting geometry isn't. The PNP-NC/NO, 3-wire output must match the control input, while cable leads call for a termination plan rather than a connector assumption.

Box packaging and cable leads shape the receiving and termination work. Specify how the line will handle and connect E2EW-X20B3D30 2M before putting it on a production BOM. The LED gives local indication, but cannot settle an electrical interface mismatch.

Wiring and target behavior remain open

The interface remains open despite the clear Active status. A wiring diagram, output-load rating and target-dependent sensing curve are still needed to settle the input and target-clearance decisions.

View the Win-Source product page for E2EW-X20B3D30 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting EU RoHS entries before BOM release.
  • Keep event rates within the listed 2Hz response-frequency ceiling.
  • Match the 3-wire PNP-NC/NO output to the control input.