20mm sensing distance, 2Hz response ceiling, threaded M30 body; RoHS status is disputed.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
A 20mm sensing limit does not make this a fast counter
2Hz is the listed response-frequency ceiling. A slow position or presence check may fit; a rapidly passing target can escape detection even when it crosses the sensing zone. Stop here if the line depends on counting fast parts.
The 20mm sensing-distance ceiling makes a shielded inductive pickup plausible where a metal target passes close to a fixed mounting point, but it cannot establish the trip spacing for every target in the machine. It is not a guaranteed working clearance for every metal target. Check the target and mounting gap against that limit before setting the trip point.
The supply range still leaves the output load unresolved
The 10V to 30V supply range sets the rail constraint: 10V is the lower bound and 30V the ceiling, not a reason to run at either edge. The PNP-NC/NO, 3-Wire output belongs on a controller input built for that topology; a different input scheme needs more than a mechanical swap. No output-load current limit is listed, so the intended input load remains unresolved.
The M30 body commits the machine to a threaded mount
Nor does an electrical match solve mounting. The threaded M30 cylinder needs an M30 mounting position; a smaller bracket cannot simply absorb it. The stainless steel body and IP67 ingress rating suit an exposed industrial mounting point, but neither establishes sensing distance for a particular target. Cable leads put routing and termination in the installation plan. The stated 0°C to 85°C operating range rules out a location that must sense below 0°C.
Active status cannot settle the RoHS contradiction
The compliance evidence conflicts, even though lifecycle status is clear. One field says RoHS Compliant; the specification says RoHS Non-Compliant. All listed lifecycle signals agree on Active, but Active doesn't establish EU RoHS compliance. Hold new-design release until Omron establishes whether this part meets EU RoHS.
For existing production, E2EW-X20B3T30 2M arrives in box packaging with cable leads. Define lead termination in the assembly instructions rather than leaving the running line to improvise it.
The 20mm limit needs target and mounting evidence
20mm is the listed sensing-distance ceiling, but a target-material correction curve and mounting-clearance drawing are absent. Obtain both before fixing the trip gap. A cable wiring diagram is also absent; obtain it before assigning the PNP-NC/NO leads.
View the Win-Source product page for E2EW-X20B3T30 2M.
Key Takeaways for Engineers & Buyers
- Check the target and mounting gap against the listed 20mm sensing distance.
- Reject fast-counting duties that exceed the 2Hz response ceiling.
- Resolve the conflicting RoHS entries before releasing the BOM.