Omron E2EW-X20B3T30 5M: New Design-In on Hold

E2EW-X20B3T30 5M Omron product image

20mm sensing distance, 2Hz response, M30 mount, 0°C to 85°C operating range; RoHS status conflicts.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 20MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

20mm reach does not clear the RoHS hold

20mm is the listed sensing distance, not a promise that every metal target will switch at that gap. The E2EW-X20B3T30 5M is Active, and its lifecycle signals agree. The hold is compliance, not lifecycle. One RoHS field says compliant; the specifications say non-compliant. Hold new design-in and EU RoHS sign-off until the conflict is resolved.

2Hz limits the counting job before reach does

2Hz is the listed response frequency. A 20mm reach doesn't make the sensor suitable for a faster target count. The supply range is 10V to 30V, with 30V as its ceiling rather than a working setpoint. The stated operating range of 0°C to 85°C rules out a cold start below 0°C. These ratings narrow the application, but they don't establish switching behavior for a particular moving target.

M30 and IP67 point to a fixed machine position

That leaves a fixed machine position as the practical fit: a shielded stainless-steel body with a threaded M30 mount and IP67 ingress protection. Cable leads rule out a connector-ready assembly assumption. Termination is part of installation.

20mm clearance still needs target and installation details

Target clearance remains open: the datasheet still needs a target-material sensing-distance curve before the listed 20mm reach can set the actual mounting gap. Without the cable-lead wiring diagram, the PNP-NC/NO hookup remains unresolved, while the missing M30 mounting drawing leaves both the enclosure opening and mounting clearance open. No output-current limit is stated, so the load cannot be checked against a listed drive limit.

Cable leads shape production as well. Put the termination method into the assembly instruction before the line is set up; otherwise, the electrical hookup becomes a separate installation decision at each machine on the line.

View the Win-Source product page for E2EW-X20B3T30 5M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting EU RoHS entries before sign-off.
  • Check target transitions against the listed 2Hz response frequency.
  • Keep the supply within its listed 10V to 30V limits.