20mm sensing distance, 10V–30V listed supply range, M30 threaded body; 2Hz response ceiling.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Can this active sensor go on a new BOM?
Can it go on a new BOM? Not yet. E2EW-X20C130 2M has consistent Active lifecycle entries, but its compliance field says RoHS Compliant while its specifications say RoHS Non-Compliant. Neither entry settles the conflict. Resolve it before release.
The supply range still has to match the input
Once that conflict is resolved, the electrical fit still matters: the listed supply range is 10V to 30V, with 30V as its upper limit, and a rail outside that range rules out the connection. The NPN-NO, 3-wire output must suit the receiving input; sensing distance can't fix an input mismatch. Cable leads also make wiring part of the installation.
A 20mm reach still needs a workable mounting position
The 20mm sensing-distance ceiling constrains target placement. It is not an assured trip point for every target; place the target too far from the face and detection fails before output wiring matters. The threaded M30 cylinder needs a matching mount. Shielding and the stainless-steel body describe the hardware being mounted, not a smaller-footprint option.
The stated operating-temperature range is 0°C to 85°C, so a location outside it rules out this installation. IP67 gives the enclosure an ingress-protection rating, but it says nothing about protection at the installed cable termination. For this fixed industrial proximity-sensing choice, the target position must fit the listed boundaries, as must the mount and environment.
2Hz leaves moving-target behavior unresolved
2Hz is the listed response-frequency ceiling. It cannot justify detection of targets passing faster than that limit, nor is it a switching waveform. The target-dependent sensing curve and output load rating are absent, leaving target clearance and input loading unresolved. The cable-lead pinout and M30 mounting drawing are also absent, leaving fixture details open. Resolve the RoHS conflict before committing an assembly with the box-packaged, cable-lead E2EW-X20C130 2M.
View the Win-Source product page for E2EW-X20C130 2M.
Key Takeaways for Engineers & Buyers
- Hold E2EW-X20C130 2M release until the RoHS entries agree.
- Check target motion against the 2Hz response-frequency ceiling.
- Match the NPN-NO, 3-wire output to the input circuit.