Omron E2EW-X22B1D30 5M: active, with a RoHS conflict

E2EW-X22B1D30 5M Omron product image

22mm sensing distance, 10V ~ 30V supply and M30 threaded body; response frequency is 2Hz.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

22mm sensing distance makes this a candidate, not a finished selection

22mm is the listed sensing distance. It puts this inductive sensor in contention where a target must be detected without contact, but it doesn't settle detection across the actual target material or mounting arrangement. E2EW-X22B1D30 5M is marked Active across its lifecycle entries; resolve the separate compliance conflict before new design-in.

The 10V ~ 30V supply range sets the permitted rail span, not the load the output can drive. A controller rail outside that range rules the part out before mechanical fit matters.

2Hz limits the trigger job despite the IP67 enclosure

2Hz is the weak point: the listed response frequency rules out triggers that must detect faster events. IP67 and a stainless-steel body support an exposed industrial installation, but neither changes that limit.

The M30 body fits only if the input and mounting agree

That speed limit narrows the fit to position sensing where a PNP-NO, 3-wire signal matches the controller input and a threaded M30 cylinder fits the machine. A controller expecting a different output polarity or contact behavior is incompatible, regardless of mounting. Cable leads make this a wired installation, not a connector-ready sensor.

The listed 0°C ~ 85°C operating range bounds installation temperature, but without a sensing-distance curve, it does not show how sensing distance behaves across that range when the target sits near the detection boundary. A mounting drawing is also absent, so the M30 description alone cannot settle clearances. The wiring diagram and output-load rating are missing too; both are needed before assigning controller terminals and load.

Can the conflicting RoHS entries clear a production BOM?

Can E2EW-X22B1D30 5M clear an EU RoHS production BOM? Not from these entries: the compliance field says compliant, while the specification says non-compliant. That conflict, not the Active lifecycle status, is the buying constraint. Obtain a corrected compliance declaration before approval; box packaging does not resolve it.

View the Win-Source product page for E2EW-X22B1D30 5M.

Key Takeaways for Engineers & Buyers

  • Check the machine's trigger rate against the listed 2Hz response frequency.
  • Keep the supply within the listed 10V ~ 30V range.
  • Resolve the conflicting RoHS entries before approving the BOM.