Omron E2EW-X22B230 2M: Active, but RoHS blocks design-in

E2EW-X22B230 2M Omron product image

22mm sensing distance, 10V to 30V supply, M30 body, and 0°C to 85°C operation.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status does not settle E2EW-X22B230 2M compliance

Even so, Active lifecycle signals take a new design-in only as far as the compliance gate. One field says RoHS Compliant; another says RoHS Non-Compliant. The status is unresolved, not established as non-compliant.

Get a manufacturer compliance declaration before releasing the production BOM. The lifecycle fields agree on Active. RoHS is the conflict that can stop an otherwise suitable sensor from passing qualification.

The 2Hz response favors slow position checks

The 2Hz response frequency rules out high-rate counting. A fixed industrial position check is the stronger fit: the shielded inductive sensor has a threaded M30 stainless-steel body rather than a board mount.

The 22mm sensing distance is a clearance to test, not a guaranteed trip point for every metal target. Mounting position and target choice determine whether the machine detects the change reliably. Cable leads also matter to the installation; this isn't a plug-in board sensor.

Supply bounds and output logic decide the controller fit

10V to 30V is the listed supply range. The 30V upper bound is a ceiling, not a level for rail transients to cross; below 10V, the sensor is outside the stated range. Keep the controller supply within both limits.

The stated operating range runs from 0°C to 85°C. It rules out a cold-start requirement below 0°C and caps the stated operating temperature at 85°C. IP67 describes ingress protection, not permission to exceed those temperature bounds.

E2EW-X22B230 2M has a PNP-NC, 3-wire output. Match the controller input and its logic to that normally closed output before committing the wiring, because a polarity mistake can make a target change register as the opposite machine state. The LED provides a local indication but does not settle the electrical interface.

Missing load and mounting details hold up sign-off

Not yet. The output load limit and wiring diagram are absent, so the PNP-NC interface cannot be signed off. Target-material correction data and an M30 mounting drawing are also absent; the 22mm clearance and mechanical fit remain unproven.

View the Win-Source product page for E2EW-X22B230 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the opposing RoHS fields before BOM approval.
  • Check the 22mm sensing distance against the actual metal target.
  • Match the controller input to the PNP-NC, 3-wire output.