22mm sensing distance, 2Hz response limit, M30 threaded body, 0°C ~ 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 22MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
The 22mm reach does not settle the target gap
22mm is the listed sensing distance, not a gap to copy into a fixture drawing. It sets a reach limit but no detection margin for the metal target in your machine. The 2Hz response frequency is a ceiling that can rule out a fast-moving target, but it tells you nothing about output behavior at the edge of detection. Don't set the gap there.
The 10V ~ 30V supply bounds tell you whether the control rail is in range, not whether excursions outside that range are acceptable. The 0°C ~ 85°C operating range covers the intended environment only if the mounting location stays within it. These limits narrow the choice, but they do not finish the installation.
The M30 body belongs in a threaded machine fixture
Fast index counting is the wrong job. The shielded inductive head and M30 threaded cylinder suit a fixed metal-target position where a fixture holds the gap. IP67 addresses enclosure ingress; cable leads and the PNP-NC/NO, 3-wire output require a matching controller input and wiring scheme.
Active status clears one hurdle; RoHS blocks another
Can this go on a new BOM? E2EW-X22B3D30 2M has consistent Active lifecycle entries, so there is no lifecycle reason here to restrict it to sustaining designs. The purchasing hold is different: the compliance field says RoHS Compliant, while the specifications say RoHS Non-Compliant. Those entries cannot support the same release decision.
Get the RoHS status resolved with Omron before committing a restricted-materials build. A box package does not change that decision.
The 22mm figure still needs a sensing curve
At 22mm, the listed sensing distance still cannot settle the fixture gap without a sensing-distance curve for the intended target metal. Output response timing beyond the 2Hz frequency limit is missing, as are a cable-lead wiring diagram and a dimensioned M30 drawing. Those gaps leave reliable target detection, controller interpretation of the transition, and mounting fit unresolved.
View the Win-Source product page for E2EW-X22B3D30 2M.
Key Takeaways for Engineers & Buyers
- Set the target gap below the listed 22mm sensing-distance limit.
- Keep detection demands within the listed 2Hz response-frequency limit.
- Resolve the opposing RoHS entries before releasing a restricted-materials build.