22mm sensing distance, 2Hz response ceiling, M30 threaded body; RoHS records conflict.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 22MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in, but RoHS needs a ruling
The RoHS entries conflict. Every lifecycle signal for E2EW-X22C130 2M, though, says Active. New design-in is reasonable to consider, but that status doesn't clear the part for a build requiring EU RoHS. Settle the compliance question before committing it to that build.
For an existing production line, the lifecycle record alone gives no reason to force a change. The practical question is whether the sensing distance and response rate fit the machine.
The 2Hz ceiling rules out fast event counting
Fast event counting is the wrong job here. Events beyond the listed 2Hz response-frequency ceiling cannot be treated as reliably detected; slower presence detection is more credible. The listed 22mm sensing distance sets a reach limit, not a promise that every target will switch at 22mm.
E2EW-X22C130 2M is a shielded inductive sensor with an NPN-NO, 3-wire output. Match that output to the controller input: sensing distance alone cannot establish electrical fit.
Can this M30 sensor go onto the approved BOM?
Can this go on the approved BOM? Not for a build requiring EU RoHS until the conflicting entries are resolved: one says Compliant, the other Non-Compliant. Neither can be quietly chosen over the other. Get a definitive EU RoHS status before approving E2EW-X22C130 2M for a controlled build; Active lifecycle status does not settle a materials requirement.
The installation needs its own check. The M30 threaded cylinder requires a matching mount, and cable leads call for a wiring plan rather than a connector assumption. “Box” describes the package, not the termination. A stainless-steel body and IP67 ingress rating support an exposed machine location, but neither establishes that the intended target will be detected at the required position. Ordering the wrong mechanical or electrical arrangement stalls assembly even when the part itself is the intended sensor.
10V to 30V supply limits frame the electrical fit
30V is the supply ceiling, not a target. The listed range starts at 10V, so a rail outside 10V to 30V rules out this sensor; a rail inside it still does not establish compatibility with the controller input or connected load.
The listed operating-temperature range is 0°C to 85°C. An installation outside it is out of bounds, while one inside it still needs its sensing and output requirements checked. The LED indicator helps observation but cannot make a marginal detection point reliable.
The missing drawing and load limit still matter
The M30 callout cannot finish the mechanical layout without a mounting drawing. A wiring diagram and output load-current limit are also absent, leaving the controller connection unresolved. Target-dependent sensing data would show whether the listed 22mm distance holds for the intended target.
View the Win-Source product page for E2EW-X22C130 2M.
Key Takeaways for Engineers & Buyers
- Hold EU RoHS-controlled BOM approval until the conflicting statuses are resolved.
- Match the NPN-NO, 3-wire output to the controller input.
- Check the machine's event rate against the 2Hz response ceiling.