Omron E2EW-X22C130 5M: Active, but RoHS status conflicts

E2EW-X22C130 5M Omron product image

22 mm sensing distance, 2 Hz response, M30 threaded body; 10 V to 30 V listed supply range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 22MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

The 2 Hz response rules out rapid part counting

Rapid part counting is the wrong job. The listed 2 Hz response frequency won't support counting fast-moving targets. Omron E2EW-X22C130 5M fits slower machine-position or presence checks when its NPN-NO, 3-Wire output matches the controller input and its shielded, M30 threaded stainless-steel body fits the mounting point. The 22 mm sensing distance is a selection figure, not a promise for every target and mounting arrangement; a misplaced trip point can report a missing part when one is present.

All listed lifecycle signals say Active, supporting new design-in on lifecycle grounds. The EU RoHS entries disagree: one says compliant, the other non-compliant.

The 30 V supply ceiling does not set the rail

30 V is the listed supply ceiling, not a preferred rail. The 10 V lower bound gives no support for operation below the stated range. Likewise, the 85°C operating-temperature ceiling limits placement near hot machinery, while the 0°C lower boundary says nothing about cold starts below it. IP67 is the ingress-protection rating; the installed cable entry still needs attention.

The RoHS conflict is the buying constraint

Can this part go on a compliance-controlled line? Not yet. The RoHS entries contradict each other; obtain a manufacturer EU RoHS declaration for E2EW-X22C130 5M before releasing the build. Box packaging isn't the obstacle.

The 22 mm figure cannot settle the trip point alone

The wiring detail is missing, but the NPN-NO, 3-Wire output and cable leads establish the interface type. A wiring diagram must settle lead assignments before connection to a controller; a dimensioned M30 mounting drawing must settle the geometry before metalwork is released. Target-material sensing curves are absent too, so the 22 mm figure alone cannot settle the trip point.

View the Win-Source product page for E2EW-X22C130 5M.

Key Takeaways for Engineers & Buyers

  • Match the controller input to the NPN-NO, 3-Wire output.
  • Check the machine cycle against the listed 2 Hz response frequency.
  • Obtain a manufacturer EU RoHS declaration to resolve the conflicting entries.