2mm sensing distance, 10V ~ 30V supply limits, threaded M12 body
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in; the RoHS conflict stops sign-off
Can E2EW-X2B112 5M go on a new machine BOM? All listed lifecycle signals say Active, so new design-in is defensible on lifecycle grounds, but the compliance field says RoHS Compliant while the specification says RoHS Non-Compliant. Hold EU RoHS sign-off until Omron resolves the conflict. That hold is not evidence that the sensor is nearing end-of-life.
For existing production, keep the exact threaded M12, cable-lead configuration on the BOM while the compliance answer is obtained. “Box” describes packaging, not the connection to the controller; treating it as an electrical variant risks ordering the wrong assembly.
The 2mm distance makes target placement the first constraint
And the electrical envelope doesn't rescue loose target placement: the listed 2mm sensing distance is a close-range starting point, not guaranteed detection for every target. The 10V ~ 30V supply limits decide controller-rail compatibility, not output load capacity.
A 100Hz response limit rules out faster sensing tasks
Fast counting and freezing installations are wrong bets here. The listed 100Hz response frequency limits the sensing task; it doesn't specify minimum pulse width. The 0°C ~ 85°C operating-temperature range excludes use below its lower bound. For a nearby metal target, the shielded inductive head and threaded M12 cylinder offer a clear mounting starting point. PNP-NO, 3-wire output still has to suit the controller input. IP67 and a stainless steel body help frame exposure, but neither establishes cleaning-chemical compatibility.
The M12 body still needs a drawing and switching detail
A dimensional drawing is absent, despite the tidy M12 description. The mount and cable exit cannot be fixed from this page. Output-load limits are also absent; the PNP-NO label alone cannot close the electrical interface. Hysteresis and target-dependent sensing curves are missing too, leaving the 2mm distance insufficient to set a repeatable trip point.
View the Win-Source product page for E2EW-X2B112 5M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting RoHS entries before approving the new BOM.
- Check target placement against the listed 2mm sensing distance.
- Match the controller input to PNP-NO, 3-wire output and 10V ~ 30V supply limits.