2 mm inductive sensing in an M12 threaded body; 10 V to 30 V supply and 0°C to 85°C operation.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
Can this active sensor go on a new machine BOM?
Can it go on the new machine BOM? On lifecycle grounds, yes: E2EW-X2B312 2M is Active, with no conflicting lifecycle signals. RoHS approval is another matter. One field says RoHS Compliant; the specifications say RoHS Non-Compliant. Resolve that conflict before approving a build that requires EU RoHS. Without that approval requirement, the electrical and mounting fit still need checking.
Will 2 mm reach the target at machine speed?
2 mm is the listed sensing distance, not a guaranteed switching gap for every target. Check the actual target and mounting position before fixing the sensor location. Too much separation can cause missed detections. Then compare the listed 100 Hz response frequency with how often targets pass; a suitable gap alone does not establish timing.
Where does the M12 body earn its place?
That short gap favors a controlled position beside a passing target. The shielded stainless-steel body has M12 threads for mounting, while its PNP-NC/NO, 3-wire output must match the input circuit. Call out the cable-lead termination on the build drawing. It’s not a connector-ended part. The sensor ships in a Box; specifying the cable-lead version keeps a connector assumption from reaching assembly.
Does the supply range survive the installation?
30 V is the ceiling of the listed 10 V to 30 V supply range, not a setpoint; 10 V is the lower bound. Use those limits to screen the machine rail, but don’t assume tolerance to excursions beyond them.
The operating range is 0°C to 85°C. Its upper limit is 85°C, and an installation expected to run below 0°C falls outside the stated range. IP67 is the listed ingress-protection classification and can inform the choice of an exposed mounting position, but it says nothing here about chemical exposure or whether a washdown process will suit it. These entries define limits for the location; they do not establish that any industrial enclosure will suit the sensor.
What still stops the installation drawing?
Missing connection and mounting details stop the installation drawing. There is no wiring diagram for the 3-wire output or mechanical drawing for the M12 mounting. Target-dependent sensing-distance data and an output-load current limit are also absent, leaving the input connection and detection position unsigned.
View the Win-Source product page for E2EW-X2B312 2M.
Key Takeaways for Engineers & Buyers
- Resolve the RoHS conflict before approving E2EW-X2B312 2M.
- Test the 2 mm sensing distance with the actual target.
- Match the machine rail to the 10 V to 30 V supply range.