2mm inductive reach, 10V to 30V supply span, M12 threaded body, and 0°C to 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M12 |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
A 2mm reach makes design-in possible, not automatic
2mm is the listed sensing distance. That makes this Omron inductive sensor a new design-in candidate only where the installed target stays within reach. The lifecycle signals agree on Active, supporting its use in existing production. Reach alone does not establish performance against every target or mounting arrangement.
EU RoHS remains unresolved: one compliance field says compliant, while the specification list says non-compliant. Settle that contradiction before release.
The M12 mount is useful only if the electrical limits fit
That short reach puts target geometry ahead of enclosure choice. The shielded, stainless-steel M12 threaded cylinder gives the machine builder a defined mounting style, but it won't rescue a target positioned beyond the listed 2mm sensing distance. The IP67 designation addresses ingress protection, not sensing performance.
The listed 10V to 30V supply span sets the electrical boundary: 30V is the upper ceiling, not a setpoint. A supply outside that span has no support here. The 0°C to 85°C operating range likewise rules out installations beyond those temperatures without further evidence. The listed 100Hz response frequency does not specify switching delay, so faster detection is a poor assumption. Before this sensor goes on the machine, its PNP-NC/NO, 3-Wire output must match the controller input.
Can the line accept cable leads instead of a connector?
Can the line terminate cable leads? For E2EW-X2B312 5M, that is the practical build question. Put the listed termination and cable route into the assembly instructions rather than assuming a plug-in sensor change. The threaded M12 body also needs a compatible mounting point. On a running line, a sensor that fits electrically but can't be terminated or mounted as built stops installation rather than fixing detection.
The missing load limit still blocks output selection
The absent output-current limit is the weak point, though the listed PNP-NC/NO, 3-Wire type identifies the interface to investigate. An output-load decision still needs that limit. Switching timing, a cable-lead wiring diagram, and a mechanical drawing are also absent, leaving controller timing and installation details open.
View the Win-Source product page for E2EW-X2B312 5M.
Key Takeaways for Engineers & Buyers
- Check the 2mm sensing distance against the installed target gap.
- Keep the supply within the listed 10V to 30V span; 30V is the upper ceiling.
- Resolve the opposing RoHS entries before releasing E2EW-X2B312 5M.