Omron E2EW-X2C212 2M: Active, but RoHS status conflicts

E2EW-X2C212 2M Omron product image

2mm sensing distance, 10V to 30V supply limits, M12 threaded body; RoHS entries conflict.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

The 2mm gap decides whether this sensor belongs on the fixture

2mm is the listed sensing-distance ceiling for the E2EW-X2C212 2M. If the fixture lets the target move beyond that gap, there’s no detection margin to spend. The 10V to 30V supply limits establish whether the controller rail is eligible, not how the sensor switches at every voltage in that range.

The 0°C to 85°C operating-temperature range rules out a specified cold start below 0°C. Those limits matter more here than the stainless-steel body: a durable housing cannot rescue a missed target or a sensor powered outside its stated range.

Active lifecycle, unresolved RoHS

Release stays conditional. Omron E2EW-X2C212 2M has aligned Active lifecycle fields, but one compliance field says RoHS Compliant while another says RoHS Non-Compliant, so EU RoHS compliance remains unresolved. Settle the conflict before release.

Order the M12 cable-lead version, not a connector assumption

Will this M12 cable-lead version fit the current assembly? Box is the listed packaging; cable leads are the termination. Match the order description to the threaded M12 body and route the cable before releasing the BOM. A connector-ended installation would need a change at the sensor connection; this part does not provide one.

The NPN-NC input and missing drawings still decide the fit

This part is wrong for a controller input that expects normally open logic. Its NPN-NC, 3-wire output belongs on an input designed for that switching convention; a mismatch can report the target state backwards. The shielded, threaded cylinder suits close-range metal detection where a fixture can hold the body and route the cable. IP67 addresses ingress; it does not establish cleaning-fluid compatibility.

The listed 100Hz response frequency is a ceiling, not proof that every brief target pass will register. Response timing is absent. So are the output load-current limit, wire-identification diagram and mechanical drawing. The current limit determines whether the sensor can drive the intended input; the diagram and drawing settle the wiring and bracket details before either is built.

View the Win-Source product page for E2EW-X2C212 2M.

Key Takeaways for Engineers & Buyers

  • Keep the target within the listed 2mm sensing-distance ceiling.
  • Resolve the conflicting RoHS entries before releasing the BOM.
  • Get the output load-current limit before connecting the NPN-NC input.