Omron E2EW-X2C312 5M: Active, hold buying over RoHS

E2EW-X2C312 5M Omron product image

2mm sensing distance, 10V ~ 30V supply limits, M12 threaded body; RoHS entries conflict.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M12
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V

Can this active Omron sensor go on a new BOM?

Can we buy this for a new BOM? Not yet. E2EW-X2C312 5M is marked Active across the lifecycle fields, so its status does not rule out a new design-in or continued use in existing production. The hold is about compliance: one field says RoHS Compliant, while the specification says RoHS Non-Compliant. Resolve that conflict before releasing the BOM. Neither entry can stand in for the other.

The part comes boxed with cable leads. Plan for a wired termination at the machine, not a connector at the sensor.

The 2mm reach sets placement before the M12 body does

Placement comes first. The listed 2mm sensing distance sets a placement ceiling, not a guaranteed working gap across every target and mounting condition; without further sensing data, a target placed at that edge risks intermittent detection. The shielded, stainless-steel M12 threaded body suits a mounted industrial sensing point. Its NPN-NC/NO, 3-Wire output must match the input circuit. IP67 is the listed ingress protection, but it doesn't remove the need to account for the cable termination.

The supply listing starts at 10V and has a 30V ceiling. A rail below 10V falls outside that range, and 30V is not an overvoltage allowance. Treat the 100Hz response-frequency figure as a ceiling for event-rate screening, not as a switching waveform. The operating-temperature range is 0°C to 85°C; locations outside those endpoints are not covered.

3-Wire output still leaves a wiring gap

3-Wire is not a pinout. For E2EW-X2C312 5M, the pinout and mounting drawing are absent here. So are an output-current rating and target-dependent sensing data. The input connection, mechanical clearance and dependable detection point remain open decisions.

View the Win-Source product page for E2EW-X2C312 5M.

Key Takeaways for Engineers & Buyers

  • Check the target position against the listed 2mm sensing distance.
  • Match the NPN-NC/NO, 3-Wire output to the machine input.
  • Resolve the conflicting EU RoHS entries before BOM release.