5mm sensing, 10V ~ 30V supply bounds, M18 body; 0°C ~ 85°C operating temperature.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V |
Active status does not clear this sensor for a new BOM
Can this sensor go into a new machine BOM? Not yet. The lifecycle signals agree on Active, but the compliance field calls it RoHS Compliant while the specifications call it RoHS Non-Compliant; EU RoHS status remains unresolved. Keep existing production on its approved configuration, and hold new design-in until the conflict is resolved.
The 10V ~ 30V supply bounds rule out rails beyond that range, but they tell you nothing about lead polarity or allowable output load. The 0°C ~ 85°C operating range also excludes colder installations. Neither rating resolves the compliance conflict.
The boxed version needs a precise purchase description
Keep the approved build. E2EW-X5B218 5M comes boxed with cable leads, so the purchase description must specify that termination, not a connector. Get a resolved EU RoHS declaration before releasing a new BOM.
The 80Hz ceiling puts fast target counts out of reach
This sensor is wrong for target counts above its 80Hz response-frequency ceiling. For slower metal-target detection, the listed 5mm sensing distance sets a placement limit, not a promise that every target switches at the edge.
The M18 threaded, shielded stainless-steel body belongs at a mounted machine sensing point. Its PNP-NC, 3-Wire output must match the receiving input. A physical fit won't fix the wrong switching behavior.
IP67 is stated; installation detail is not
Installation detail is missing. The stated IP67 ingress rating gives the enclosure choice a boundary, but it doesn't establish suitability for every cleaning process. The datasheet still needs to supply a lead-color wiring diagram, a dimensioned mounting drawing, and sensing-distance behavior for different target materials.
Without those details, a miswired cable can stall commissioning, while a bracket set from the nominal sensing distance can leave the target undetected.
View the Win-Source product page for E2EW-X5B218 5M.
Key Takeaways for Engineers & Buyers
- Resolve the conflicting RoHS entries before releasing a new BOM.
- Check the 80Hz response-frequency ceiling against the target pass rate.
- Get the lead-color wiring diagram before terminating the 3-Wire cable.