Omron E2EW-X5B318 5M: Active, with a RoHS conflict

E2EW-X5B318 5M Omron product image

5mm sensing limit, 80Hz response limit, M18 threaded body, 0°C to 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 5MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V

The 5mm gap sets the fixture question

5mm is the listed sensing-distance ceiling, not a guaranteed switching gap for every target. Check the actual target and mounting geometry before drilling the fixture; a moving feature can still pass the sensor face without registering if it outruns the 80Hz response-frequency ceiling. The 0°C to 85°C operating range rules out colder machine locations and caps the hot end, but says nothing about margin at a particular mount.

IP67 is the stated ingress rating. It doesn't settle the finished cable route. A station trial can test the installed gap and moving feature together, but those listed limits alone cannot settle the fixture.

Active status does not settle the RoHS conflict

The RoHS entries disagree: the compliance field says compliant, while the specifications say non-compliant. Lifecycle is clearer; every entry says Active. E2EW-X5B318 5M remains a new-design candidate, but Omron must resolve the EU RoHS discrepancy before it can enter a controlled BOM.

The M18 body belongs on a machine mount

It belongs at the machine. The M18 threaded cylinder and cable leads suit a fixed sensor mount with wiring brought back to a controller, not a plug-in board position. Its PNP-NC/NO, 3-Wire output needs a matching input and the intended contact behavior established before an existing channel is reused. The stainless-steel body and LED help with mounting and local indication, but neither establishes the trip distance for a particular target material.

Cable leads are the running-line constraint

10V to 30V bounds the controller supply rail; it isn't a recommended setpoint. On a running line, cable-lead termination is the buying constraint, not the Box package entry. Specify the termination on the order and match it to the installed connection before moving the sensor. A threaded body that fits but cannot be wired still stops the changeover.

The 5mm limit still needs a target curve

Target-dependent trip distance remains the bracket constraint. The listing lacks target-material correction and sensing-distance curves, so the 5mm ceiling cannot fix the bracket position on its own. It also lacks a cable-lead wiring diagram and mounting drawing; the M18 thread and PNP output description cannot establish connections or physical clearances.

View the Win-Source product page for E2EW-X5B318 5M.

Key Takeaways for Engineers & Buyers

  • Treat 5mm as the sensing-distance limit when setting target clearance.
  • Compare the machine's event rate with the 80Hz response limit.
  • Resolve the conflicting RoHS entries before BOM release.