Omron E2EW-X5C218 5M: Active, but RoHS status conflicts

E2EW-X5C218 5M Omron product image

5mm sensing, 10V to 30V supply, M18 threaded body; 0°C to 85°C operating range.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 5MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V

Active lifecycle, contradictory RoHS record

And that leaves a split decision: all lifecycle signals say Active, so the device is a candidate for new design-in, but the RoHS record won't support compliance sign-off. One field says RoHS Compliant; the specification says RoHS Non-Compliant. EU RoHS status remains unresolved, rather than confirmed as a pass or a failure.

An industrial inductive sensor with a shielded M18 threaded cylinder can sit near a metal target at a threaded mounting point, but the listed 5mm sensing distance does not establish detection on the actual target. Test that gap on the target. The NPN-NC, 3-Wire output needs a controller input that interprets normally closed logic correctly; otherwise, the machine may read the idle state as a target event.

The response figure is not a switching-delay guarantee

The 80Hz response frequency isn't a switching-delay waveform; it does put fast-moving targets on the test plan before the mechanism is frozen. The 10V to 30V supply range permits a controller-rail check, not an output-load judgment. The 0°C to 85°C operating range rules out installations beyond those limits. No pinout, output load limit or target-dependent sensing curves appear here, so the electrical hookup and trip point remain open.

The M18 mount fixes more than the sensor position

A 5mm sensing distance against an M18 threaded mount puts bracket placement under pressure. A stainless-steel body and IP67 ingress rating support a machine-mounted pickup exposed to dust and water, but do not establish resistance to chemicals used around it. Cable leads shift termination work onto the assembly line rather than a mating connector. Without a mounting drawing, bracket clearance and thread engagement remain open.

Can the line terminate cable leads?

Does it come with a connector? No: E2EW-X5C218 5M is listed with cable leads and Box packaging. Specify termination before BOM release; resolve the conflicting RoHS entries before compliance sign-off.

View the Win-Source product page for E2EW-X5C218 5M.

Key Takeaways for Engineers & Buyers

  • Test the 5mm sensing distance on the actual target.
  • Match the NPN-NC, 3-Wire output to the controller input.