5mm sensing distance, 10V ~ 30V supply, M18 thread; RoHS entries conflict.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC/NO, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V |
Active status does not settle this sensor's RoHS conflict
A build requiring confirmed EU RoHS can't clear this part today: one compliance field says compliant, while the specification says non-compliant. E2EW-X5C318 2M is Active and a candidate for new design-in, not just sustaining work. Resolve the conflict before production release.
The M18 body fits industrial mounting, not every input
The 80Hz response frequency is the weak point for fast-moving targets; it gives no switching-time figure. The shielded M18 threaded stainless-steel body has IP67 protection, useful where a machine bracket puts the sensor near exposure. Its NPN-NC/NO, 3-Wire output needs a controller input wired for that topology. Cable leads need a field termination plan, not an assumed plug-in connection.
The 5mm sensing ceiling decides target placement
5mm is the listed sensing-distance ceiling. It is not a promise that every target will switch at that separation. For E2EW-X5C318 2M, target-to-face geometry is the first mechanical check because a moving target that cannot stay within the stated distance needs a different arrangement, not a looser reading of the rating.
The 10V ~ 30V supply range bounds the rail choice; neither end authorizes excursions beyond the listed range. The operating-temperature range of 0°C ~ 85°C leaves a colder start or hotter location outside its stated envelope. Those figures decide whether this sensor can be placed and powered. They do not establish switching behavior for the actual target material or at the machine's required speed.
Cable leads leave wiring and timing open
The 80Hz figure leaves switching time unspecified. Cable leads need a field termination plan before panel wiring is fixed. The listing gives no lead assignment for the NPN-NC/NO output and no M18 mounting drawing. Get the lead assignment and switching-time detail before wiring; obtain the mounting drawing before bracket release. E2EW-X5C318 2M remains a new-build candidate, subject to resolution of the conflicting RoHS entries.
View the Win-Source product page for E2EW-X5C318 2M.
Key Takeaways for Engineers & Buyers
- Keep target travel within the listed 5mm sensing-distance ceiling; check response with the actual target.
- Check the machine rail against the listed 10V ~ 30V supply range.
- Resolve the conflicting RoHS entries before production release.