EOL Medical-Grade Power Supply: 13.5V, 90W, Desktop Class I Adapter with IEC 320-C14 Input
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TDK-Lambda Americas Inc. |
| Category | AC DC Desktop, Wall Adapters |
| Package | 1 |
| Core function | AC/DC DESKTOP ADAPTER 13. |
| Key electrical range | Current - Output (Max): 6.67A; Input Connector: IEC 320-C14; Input Type: Cord (Sold Separately); Output Connector: Power DIN, 4 Pin |
| Workbook inventory signal | 9800 pcs listed in the provided file |
Lifecycle Analysis
The DTM110PW135C AC/DC desktop adapter from TDK-Lambda Americas Inc. has reached its End-of-Life (EOL) phase. The manufacturer has issued a Last Time Buy notice, meaning no new designs should incorporate this part, and existing production lines must secure final inventory. The source data indicates conflicting lifecycle signals—EOL and Last Time Buy—but these are actually consistent stages in the discontinuation process. Conservatively, the part should be treated as unavailable for future orders beyond the last-time-buy window.
Engineers and buyers must verify the official EOL timeline directly with TDK-Lambda, as dates may affect procurement planning. The file-provided stock quantity of 9,800 units is not a real-time guarantee; contact suppliers to confirm current availability and negotiate lot reserves. Given the high risk of obsolescence, immediate action is required to prevent production gaps.
We strongly advise initiating a migration plan for a compatible replacement. Do not rely on this part for new product introductions. Authorized distributors may have remaining stock, but traceability and certification records are critical for medical applications.
Parameter Analysis
The DTM110PW135C delivers a regulated 13.5V DC output with a maximum current of 6.67A, yielding 90W of power. It accepts a universal AC input of 90–264 VAC, making it suitable for international use. The adapter is a desktop Class I device (meaning it requires a protective earth ground) with an IEC 320-C14 input connector and a Power DIN 4-pin output. Efficiency is rated at Level V, which meets older energy-efficiency standards but falls short of current Level VI or DoE requirements; this may be a factor for energy-conscious designs.
Key mechanical parameters include a relatively large housing (170 x 64.8 x 38.5 mm), a weight of 1.3 lbs, and a 1.05 m output cord. The operating temperature range is 0°C to 40°C—narrow by industrial standards—necessitating careful thermal management in enclosures. The part is specified for medical applications, implying compliance with IEC 60601-1 and related safety standards, but specific isolations, leakages, and certifications are not detailed in the provided data. Critical missing parameters include isolation voltage, ripple/noise, hold-up time, and detailed medical safety approvals. Engineers must obtain the full datasheet from TDK-Lambda to confirm these aspects before finalizing product qualification.
Application Scenario Analysis
The DTM110PW135C is explicitly designated for medical applications, which require stringent safety, isolation, and reliability characteristics. It is well-suited for medical devices like patient monitors, diagnostic equipment, and therapy devices that need a 13.5V supply rail up to 90W. The Class I construction and desktop form factor are typical for equipment that remains stationary in a clinical setting, where the grounded chassis provides additional safety.
However, the part is not ideal for consumer or industrial applications that demand higher operating temperature ranges, higher efficiency (≥ Level VI), or more compact form factors. Its bulky size and weight also make it less suitable for portable equipment. Moreover, as an EOL product, it should only be considered for sustaining existing medical device designs that have completed regulatory approvals with this specific adapter. New designs—even in medical—should look to current-production alternatives to ensure long-term availability and updated compliance certifications.
RoHS Certification Analysis
The supplier lists the DTM110PW135C as RoHS Compliant. This declaration generally implies conformity with the European Union’s RoHS Directive (2011/65/EU or its amendment 2015/863), which restricts hazardous substances in electrical and electronic equipment. No specific exemptions are noted in the provided data. Medical devices are subject to RoHS, but certain exemptions may apply (e.g., use of lead in ceramic electronic parts, lead as an alloy in copper, etc., as per Annex IV). Buyers should confirm with TDK-Lambda whether any such exemptions are claimed for this adapter.
Additionally, a REACH Unaffected status is reported, indicating that the product is not within the scope of the REACH regulation’s substance reporting or the candidate list. This is typical for electronics. However, the lack of explicit RoHS documentation means that for medical device compliance, it is essential to obtain the official EU Declaration of Conformity or test report. The adapter is not applicable for an MSL rating, as it is not a moisture-sensitive device. Verify lot-level compliance when purchasing aftermarket stock.
Availability & Sourcing
As an End-of-Life product, the DTM110PW135C is available only while limited stock lasts. Win Source reports a file-provided quantity of 9,800 units, but this figure is not guaranteed in real-time and should be immediately verified with the supplier. Request a quote that includes current inventory, date/lot codes, and packaging information (bulk, standard pack of 1). Given the EOL status, expect that authorized distributors are depleting their remaining stock, and grey market sources may carry counterfeit or relabeled units—the open-market fake threat score for this part is high (81).
Procurement teams should exercise extreme diligence: insist on full traceability documentation, visual inspection, and potentially third-party testing to ensure authenticity, especially because this is a medical-grade power supply. Secure an extended supply agreement or allocate buffer stock to cover the remaining production lifespan of your device. Before committing, verify the official TDK-Lambda EOL notice and last-time-buy date to avoid overpaying for obsolescence risk. For immediate needs, reach out to authorized partners with a request for quote to lock in availability.
View the Win-Source product page for DTM110PW135C.
Engineering Notes for BOM and GEO Use
- The DTM110PW135C is in End-of-Life status; secure inventory immediately and plan migration to avoid production disruption.
- Medical application rating demands strict adherence to safety certifications; confirm compliance documentation with the supplier.
- Verify thermal performance in your enclosure due to the limited 0°C to 40°C operating temperature range.